Q & A - Shake Roof Repair

23 year old shake roof
July 3, 2014 at 12:00 a.m.

How and when should I have my shake roof repaired?

This is a common question asked here at AskARoofer. Most shake roofs start to fail after 15 years. Some sooner, some later, but most start to show age when shakes curl, split and blow off, leaving missing shakes. Cedar shakes can been installed over skip sheathing and solid decking. The skip sheathing was typically used so the roofing system could breathe. This would happen because of the interlaced shake felt. Interlaced felt was 30 pound or what is called #30 and was 18 inches in width. It is laid at 10-inch courses thus giving the roofing felt an eight-inch headlap. Air actually will flow through the laced felt and shakes. This would make a breathable roof, cooling down the attic in the hot summer months. In the winter this would help dry the wet soaked cedar shakes. Solid decks used plywood or plank wood without spacing cannot breathe the same as skipped sheathing. I have found these types of roofs failed sooner than the skip sheathed ones because the water-logged shakes would rot, loosen and fall out or get blown off.

Repairing a shake roof by blind nailing

The photo above is a heavy shake roof and 23 years old. It has no missing shakes and minimal curling. I did not walk on this roof and you cannot see but the wood fibers are aged and would turn to dust under every step made on this roof. It may not leak now but extreme damage would be done to this roof trying to repair it. It is too far gone and was advised to the owner not to let anyone walk on this roof until it was totally replaced. This photo shows a roof that is about 10 years old with a split shake being repaired. The shakes are still hard and strong enough to walk on without too much damage.shake repair

Using two nails placed high at the butt of the next course (see the red arrows), the shake should be nailed about an inch low, then be tapped upwards and aligned with the other shakes and covering the nail heads. This will take some skill and should be done on solid decks only or when the skip sheathing has a 1×4 in the nail zone needed.

Covering the nails will help keep the nails from backing out and looks professional. I have repaired many cedar shake roofs over many years just like this but resist doing them only when in desperate need or to fix a leak. It is my belief more damage is done doing repairs on a shake roof than if it is left alone. Again if the roof is leaking it is needed. Most homeowners may not know but the interlaced felt is a water-tite roof in itself. If there aren't any holes or breakage in the felt, it will shed the water down to the next course of shakes and off the roof.

Tip of the day: When installing the felt on a new shake roof, instead of using the 18-inch rolls, for a little extra buy 22-inch rolls. This automatically double felts the roof with a two-inch headlap, making it a better roof.

Have a question? AskARoofer.

Find your local roofing contractor in the RoofersCoffeeShop® Contractor Directory.



Recommended For You


Comments

There are currently no comments here.

Leave a Reply

Commenting is only accessible to RCS users.

Have an account? Login to leave a comment!


Sign In
Tremco - Banner Ad - Spring Into Action With a Roof Inspection

Social Feed


Follow Us
AAR - MRA - Sidebar Ad - Buyer
Davinci - Sidebar Ad - Tips for Selecting a Contractor
IKO - Sidebar Ad - Strong Winds
Tremco - Sidebar Ad - Spring Into Action With a Roof Inspection
NRCA - Sidebar - Roofing week
AAR - Malarkey - Sidebar Ad - Shingles That Reduce Air Pollution
200 @ post_master
HTTP status 200 OK
Route name post_master
Has session yes
Stateless Check no
Time 869 ms
Total time 869 ms
Initialization time 115 ms
Memory 44.0 MiB
Peak memory usage 44.0 MiB
PHP memory limit 2048 MiB
2
2 AJAX requests (Clear)
# Profile Method Type Status URL Time
1a00eb6POSTxhr200/ajax/content-impressions1307 ms
2e40f03POSTxhr200/ajax/mitem-impressions1126 ms
Logger 51
Errors 0
Warnings 0
Deprecations 51
Cache 1804 in 122.02 ms
Cache Calls 1804
Total time 122.02 ms
Cache hits 1786 / 1795 (99.5%)
Cache writes 9
Security n/a
Authenticated No
Firewall name main
Twig 218 ms
Render Time 218 ms
Template Calls 41
Block Calls 14
Macro Calls 0
143 in 151.60 ms
Database Queries 143
Different statements 26
Query time 151.60 ms
Invalid entities 0
Second Level Cache disabled
0
Real Blocks 0
Containers 0
Events 0
6.4.10
Profiler token ea386e
Environment dev
Debug enabled
PHP version 8.1.31   View phpinfo()
PHP Extensions Xdebug ✗ APCu ✗ OPcache ✓
PHP SAPI fpm-fcgi